Product Overview

Avionics Test Software is a software application that supports to the aircraft test standards, and is used to control the PCR-WE/WE2 Series that enables you to conduct the test standards for the MIL-STD-704, RTCA/DO-160 and JIS W0812 standards.
Complete test processes can be accomplished by simply clicking on the tests you wish to perform from the software library.
The software enables you to easily create customized test conditions for specialized R&D evaluation tests and for simple confirmation of various applications.

Product Features and Advantages

Simple Operation

Complete test processes can be accomplished by simply clicking on the tests you wish to perform.

Supported Standards

  • Military Standard「MIL-STD-704 (A/E/F)」
  • Civilian Standard「RTCA/DO-160 (F/G)」
  • Civilian Standard「JIS W0812: 2004」

Edit & Save Test Conditions

Easily create customized test conditions for specialized R&D evaluation tests and for simple confirmation of various applications.

Output in CSV format

Test measurement data as well as test reports can be created in CSV format.

Supported Standards

Military Standards

MIL-STD-704A, MIL-STD-704E, MIL-STD-704F: Electric, Power, Aircraft, Characteristics and Utilization of Aircraft Electric Power Characteristics

Standard

Revision/Category

AC test

DC test

SAC

SVF

TAC

TVF

SXF

LDC

HDC

MIL-STD-704

Rev. A

Rev. E

Rev. F

Civilian Standard*1

RTCA/DO-160F, RTCA/DO-160G: Environmental Conditions and Test Procedures for Airborne Equipment
JIS W0812: 2004 Airborne equipment-Environmental conditions and test procedures

Standard

Revision/Category

AC test

DC test

A CF

A NF

A WF

A

D

B

Z

RTCA/DO-160
Section 16

Rev. F

Rev. G

JIS W0812 *2

2004

*1. Following standard test items are not supported
・16.5.2.3.1 Normal Surge Voltage for 230V equipment and 16.5.2.3.1 Abnormal Surge Voltage at RTCA/DO-160F and RTCA/DO-160G
・16.5.1.5.1 Normal Voltage Surge for 230V equipment and 16.5.3.3.1 Abnormal Voltage Surge at JIS W0812

*2. Japanese domestic standard corresponding to DO-160 Rev.E